RESIDENTIAL GATE OPENER FOR SWING GATES

Site Requirements
Check that the temperature range marked on the drive is suitable for the location. Do not install the drive where ambient temperatures will exceed the ratings.

Gate
This opener is designed for residential swing gates up to 3 metres wide and less than 230 kg. Using a spring balance at a point approximately 1 metre from the hinge, check that less than 8 kg force (80 N) is required to manually move the gate through its full range of movement, with the gate disconnected from the drive.

The gate should operate smoothly, opening and closing without sticking. Hinges should not have excessive play or friction. Check the mounting points and hinges for strength and stiffness. Reinforce if necessary.

Gate posts
There should not be any visible flexing of the mounting points under load.

Level and square the gate
The gate hinge pivot points should be perfectly parallel to a plumb line. When closed, the gate leaves should line up evenly and not bind against each other. The leaves should not be damaged or bent.

Gate stops
It is recommended that any of the following are used:

  • Overlapping gate leaves
  • A tag on one gate
  • Gate-stops at the limit of each leaf’s travel

POWER SUPPLY

Mains powered
If the opener is to be mains-powered, then the 3-pin power plug should be shielded from the effects of weather. The product is tested as a unit for electrical safety compliance and if the plug is cut off for hard-wiring, then the electrical safety of the unit becomes the responsibility of the installing electrician. An isolating switch is recommended, but all mains wiring should be in accordance with local regulations.

Solar Powered
Contact Merlin for the correct battery and solar panel. The size of these depends on: the duty cycle of the gates; the hours of sunlight; and the number and type of accessories fitted.