Installation
- Place batteries with like terminals (+ to +) facing each other. Make sure that unshielded terminals do make contact with each other.
- Connect blue battery coupling wire (2) between positive (+) terminal of one battery and negative (-) terminal of the other battery.
- Connect battery harness (5) to the other battery terminals. Make sure black goes to negative (-) terminal and red goes to positive (+) terminal.
- Remove top cover of drive unit and place upside down.
- Remove battery compartment lid.
- Place batteries in compartment, feed battery harness through round hole and replace screws.
- Connect SBY-3 battery harness (4) to the two pin terminal block. Make sure black goes to negative (-) terminal and red goes to positive (+) terminal.
- Connect SBY-3 charger harness (3) to the four pin terminal block as per the diagram below.
- Connect battery harness and SBY-3 battery harness.
- Secure SBY-3 charger board to underside of top cover with M3x8 taptite screws.
- Connect charger harness socket to master control board.
- Refer to EasySlider instructions for set up procedure.